MySQL的隐式转换如何实现及应用
Admin 2022-08-05 群英技术资讯 524 次浏览
show create table t1\G *************************** 1. row *************************** Table: t1 Create Table: CREATE TABLE `t1` ( `id` varchar(255) DEFAULT NULL ) ENGINE=InnoDB DEFAULT CHARSET=utf8 1 row in set (0.00 sec) select * from t1; +--------------------+ | id | +--------------------+ | 204027026112927605 | | 204027026112927603 | | 2040270261129276 | | 2040270261129275 | | 100 | | 101 | +--------------------+ 6 rows in set (0.00 sec)
奇怪的现象:
select * from t1 where id=204027026112927603; +--------------------+ | id | +--------------------+ | 204027026112927605 | | 204027026112927603 | +--------------------+ 2 rows in set (0.00 sec)
什么鬼,明明查的是204027026112927603,为什么204027026112927605也出来了
堆栈调用关系如下所示:
其中JOIN::exec()是执行的入口,Arg_comparator::compare_real()是进行等值判断的函数,其定义如下
int Arg_comparator::compare_real() { /* Fix yet another manifestation of Bug#2338. 'Volatile' will instruct gcc to flush double values out of 80-bit Intel FPU registers before performing the comparison. */ volatile double val1, val2; val1= (*a)->val_real(); if (!(*a)->null_value) { val2= (*b)->val_real(); if (!(*b)->null_value) { if (set_null) owner->null_value= 0; if (val1 < val2) return -1; if (val1 == val2) return 0; return 1; } } if (set_null) owner->null_value= 1; return -1; }
比较步骤如下图所示,逐行读取t1表的id列放入val1,而常量204027026112927603存在于cache中,类型为double类型(2.0402702611292762E+17),所以到这里传值给val2后val2=2.0402702611292762E+17。
当扫描到第一行时,204027026112927605转成doule的值为2.0402702611292762e17,等式成立,判定为符合条件的行,继续往下扫描,同理204027026112927603也同样符合
如何检测string类型的数字转成doule类型是否溢出呢?这里经过测试,当数字超过16位以后,转成double类型就已经不准确了,例如20402702611292711会表示成20402702611292712(如图中val1)
MySQL string转成double的定义函数如下:
{ char buf[DTOA_BUFF_SIZE]; double res; DBUG_ASSERT(end != NULL && ((str != NULL && *end != NULL) || (str == NULL && *end == NULL)) && error != NULL); res= my_strtod_int(str, end, error, buf, sizeof(buf)); return (*error == 0) ? res : (res < 0 ? -DBL_MAX : DBL_MAX); }
真正转换函数my_strtod_int位置在dtoa.c(太复杂了,简单贴个注释吧)
/* strtod for IEEE--arithmetic machines. This strtod returns a nearest machine number to the input decimal string (or sets errno to EOVERFLOW). Ties are broken by the IEEE round-even rule. Inspired loosely by William D. Clinger's paper "How to Read Floating Point Numbers Accurately" [Proc. ACM SIGPLAN '90, pp. 92-101]. Modifications: 1. We only require IEEE (not IEEE double-extended). 2. We get by with floating-point arithmetic in a case that Clinger missed -- when we're computing d * 10^n for a small integer d and the integer n is not too much larger than 22 (the maximum integer k for which we can represent 10^k exactly), we may be able to compute (d*10^k) * 10^(e-k) with just one roundoff. 3. Rather than a bit-at-a-time adjustment of the binary result in the hard case, we use floating-point arithmetic to determine the adjustment to within one bit; only in really hard cases do we need to compute a second residual. 4. Because of 3., we don't need a large table of powers of 10 for ten-to-e (just some small tables, e.g. of 10^k for 0 <= k <= 22). */
既然是这样,我们测试下没有溢出的案例
select * from t1 where id=2040270261129276; +------------------+ | id | +------------------+ | 2040270261129276 | +------------------+ 1 row in set (0.00 sec) select * from t1 where id=101; +------+ | id | +------+ | 101 | +------+ 1 row in set (0.00 sec)
结果符合预期,而在本例中,正确的写法应当是
select * from t1 where id='204027026112927603'; +--------------------+ | id | +--------------------+ | 204027026112927603 | +--------------------+ 1 row in set (0.01 sec)
避免发生隐式类型转换,隐式转换的类型主要有字段类型不一致、in参数包含多个类型、字符集类型或校对规则不一致等
隐式类型转换可能导致无法使用索引、查询结果不准确等,因此在使用时必须仔细甄别
数字类型的建议在字段定义时就定义为int或者bigint,表关联时关联字段必须保持类型、字符集、校对规则都一致
最后贴一下官网对于隐式类型转换的说明吧
1、If one or both arguments are NULL, the result of the comparison is NULL, except for the NULL-safe
<=> equality comparison operator. For NULL <=> NULL, the result is true. No conversion is needed.
2、If both arguments in a comparison operation are strings, they are compared as strings.
3、If both arguments are integers, they are compared as integers.
4、Hexadecimal values are treated as binary strings if not compared to a number.
5、If one of the arguments is a TIMESTAMP or DATETIME column and the other argument is a
constant, the constant is converted to a timestamp before the comparison is performed. This is
done to be more ODBC-friendly. This is not done for the arguments to IN(). To be safe, always
use complete datetime, date, or time strings when doing comparisons. For example, to achieve best
results when using BETWEEN with date or time values, use CAST() to explicitly convert the values to
the desired data type.
A single-row subquery from a table or tables is not considered a constant. For example, if a subquery
returns an integer to be compared to a DATETIME value, the comparison is done as two integers.
The integer is not converted to a temporal value. To compare the operands as DATETIME values,
use CAST() to explicitly convert the subquery value to DATETIME.
6、If one of the arguments is a decimal value, comparison depends on the other argument. The
arguments are compared as decimal values if the other argument is a decimal or integer value, or as
floating-point values if the other argument is a floating-point value.
7、In all other cases, the arguments are compared as floating-point (real) numbers.
免责声明:本站发布的内容(图片、视频和文字)以原创、转载和分享为主,文章观点不代表本网站立场,如果涉及侵权请联系站长邮箱:mmqy2019@163.com进行举报,并提供相关证据,查实之后,将立刻删除涉嫌侵权内容。
猜你喜欢
安装PLSQl程序的方法:首先下载“plsql developer”包,解压并进入程序目录;然后选中“plsql developer”的安装程序,并用鼠标进行右键;接着在安装界面中,选择“同意安装协议”;最后选择安装路径即可。
本文接下来讲解的是MySQL的隐式转换,对此感兴趣的小伙伴很可以一起来看看
SQL SUM() 函数返回数字列的总和。下文有详解方法和实例,内容详细,逻辑清晰,有需要的朋友可以参考,希望大家阅读完这篇文章后能有所收获,那么下面就一起来了解一下吧。
这篇文章主要介绍sql过滤索引的相关内容,本文简单的介绍了sql过滤索引提高查询性能的方法,感兴趣的朋友可以参考下面的示例,对大家学习sql过滤索有一定的帮助,接下来我们就一起来看看吧。
SQL自联接是一种常规联接,但表本身是连接的。下文的讲解详细,步骤过程清晰,对大家进一步学习和理解相关知识有一定的帮助。有这方面学习需要的朋友就继续往下看吧!
成为群英会员,开启智能安全云计算之旅
立即注册Copyright © QY Network Company Ltd. All Rights Reserved. 2003-2020 群英 版权所有
增值电信经营许可证 : B1.B2-20140078 粤ICP备09006778号 域名注册商资质 粤 D3.1-20240008